Output Connector; Ipd Dci-100 Input Connector Pinout; Ipd Dci-100 Output Connector Pinout - Vision VA61 User's Reference Manual

Gige camera vision appliance
Table of Contents

Advertisement

VA6x User's Reference
Pin
Name
1, 2
Cam1 IN
3, 4
Cam1 TRIG
5, 6
Cam2 IN
7, 8
Cam2 TRIG
9, 10
Ser IN 0
11, 12
Ser IN 1
13, 14
Ser IN 2
15, 16
Ser IN 3
17
+24V IN
18
Gnd
19
+24V Out
20
Gnd
Camera I/O is programmed differently (as noted in table) when connected to the VA61, versus
when connected to other Vision Appliances or a PC.

Output Connector

The output Connector provides polarity insensitive, opto-isolated, solid state relay outputs that
can handle voltages up to 30V and can control up to 300mA. The taller or top rows are the odd
numbered pins, the shorter or bottom rows are the even numbered pins.
Pin
Name
1, 2
Cam1 STR
3, 4
Cam1 Out
5, 6
Cam2 STR
7, 8
Cam2 Out
9, 10
Ser Out 0
11, 12
Ser Out 1
13, 14
Ser Out 2
15, 16
Ser Out 3
17
+5V Out
18
Gnd
19
+12
20
Gnd
Camera I/O is programmed differently (as noted in table) when connected to the VA61, versus
when connected to other Vision Appliances or a PC.
66

IPD DCI-100 Input Connector Pinout

Description
General Purpose Input to Camera 1 (Trigger In with VA61)
Trigger Input to Camera 1 (General Purpose Input with VA61)
General Purpose Input to Camera 2 (Trigger In with VA61)
Trigger Input to Camera 2 (General Purpose Input with VA61)
Input 0 for signal that can be read via RS232
Input 1 for signal that can be read via RS232
Input 2 for signal that can be read via RS232
Input 3 for signal that can be read via RS232
24V Power Input ( 1 A Maximum with Camera)
0 Volts
Connected to Pin 17
Earth connection (not connected to Pin 18)

IPD DCI-100 Output Connector Pinout

Description
Strobe Output from Camera 1 (General Purpose Output with VA61)
General Purpose output from Camera 1 (Strobe Out with VA61)
Strobe Output from Camera 2 (General Purpose Output with VA61)
General Purpose Output from Camera 2 (Strobe Out with VA61)
Output 0 that can be Controlled via RS232
Output 1 that can be Controlled via RS232
Output 2 that can be Controlled via RS232
Output 3 that can be Controlled via RS232
+5V Output Power for external devices (100 mA Max)
Ground Pin for +5
+12V Output Power for external devices (100 mA Max)
Ground Pin for +12
405-00022-00
Rev 06; 7 April 2011