Status Leds And Reset Switch; Inspect & Ilabel Function; Sherlock Function; Figure 9. Front Panel Status Leds And Reset Switch - Vision VA61 User's Reference Manual

Gige camera vision appliance
Table of Contents

Advertisement

405-00022-00

Status LEDs and RESET Switch

The Vision Appliance provides 7 LEDs on the front panel, as visual health and status indicators
(shown in Figure 9).
LED0
Application
LED1
Camera
LED2
Switch Solution
The Reset button, when depressed, will initiate a system reset/reboot. The button is recessed in
the front panel to prevent accidental contact.
iNspect & iLabel Function
As the iNspect or iLabel application opens, two of the LEDs start flashing. These represent "ap-
plication" and "camera" health. The application "heartbeat" has a 2 second cycle, at 50% duty.
The camera "heartbeat" rate is dependent upon the type of camera and external event time or line
speed, and can be rapidly flashing, or may seem to be constantly on.
The other LED indicators represent "switch solution command" and inspection results (Pass/Re-
cycle/Reject). In the iNspect and iLabel applications, the inspection results are updated with ev-
ery inspection and visually indicate the state of the outputs on the I/O connector. The inspection
results LEDs are latched after a decision, and stay latched until the next decision is available.

Sherlock Function

In Sherlock, all 6 LEDs are under your inspection program control. There are no predefined func-
tions to the LEDs in Sherlock. The LEDs are available in Sherlock as Digital I/O output channels
8 through 13.
LED
Sherlock Digital Output
LED0 amber
Channel 8
LED1 amber
Channel 9
LED2 amber
Channel 10
Rev 06; 7 April 2011
Amber
Amber
Amber
Reset Switch

Figure 9. Front Panel Status LEDs and Reset Switch

Red
Yellow
Green
Blue – Power
LED
Sherlock Digital Output
LED3 red
Channel 11
LED4 yellow
Channel 12
LED5 green
Channel 13
VA6x User's Reference
Reject
LED3
Recycle
LED4
Pass
LED5
25

Advertisement

Table of Contents
loading

Table of Contents