Industrial I/O Connections; I/O Connector Definitions - Vision VA61 User's Reference Manual

Gige camera vision appliance
Table of Contents

Advertisement

405-00022-00

Industrial I/O Connections

The VA61 interfaces I/O using the 25-pin D-Sub connector on the back panel (Figure 2, page 16).
Pin #
Direction
1
2
In
3
In
4
In
5
In
6
7
Out
8
Out
9
Out
10
Out
11
In
12
Out
13 & 14 –
15
In
16
In
17
In
18
In
19
20
Out
21
Out
22
Out
23
Out
24
Out
25
The iNspect and iLabel software defines the I/O settings in this table for trigger inputs, strobe
outputs, and decision outputs. Sherlock uses the trigger and strobe defaults in this table, or the
definitions in a VA-Genie Camera Configuration file for the I/O Connector.
Rev 06; 7 April 2011

I/O Connector Definitions

iNspect and iLabel Definition
Ground
GPI0, Sensor/Camera Trigger 1
GPI2, or Solution ID 0
GPI4, Solution ID 2 or Trigger 2
GPI6, or Solution ID 4
Ground
GPO0, or Strobe 1
GPO2, or Pass in equation default (Pass
Cam1 in Async mode)
GPO4, Strobe 2, Pass Cam2 in Async mode Out Channel 4, or Strobe 2
GPO6
User Power input on PNP option
not connected on standard NPN
Fused +12V at 0.75A
Ground
GPI1, or Change Solution input
GPI3, or Solution ID 1
GPI5, or Solution ID 3
GPI7, or Solution ID 5
Ground
GPO1, Fail in Equation default (Pass Cam1
in Async mode)
GOP3, Fail Cam2 in Async mode
GPO5
GPO7
Fused +5 V at .75 A
Ground
VA6x User's Reference
Sherlock Definition
In Channel 0, or Trigger 1
In Channel 2
In Channel 4, or Trigger 2
In Channel 6
Out Channel 0, or Strobe 1
Out Channel 2
Out Channel 6
In Channel 1
In Channel 3
In Channel 5
In Channel 7
Out Channel 1
Out Channel 3
Out Channel 5
Out Channel 7