Appendix C. Sherlock Digital I/O Assignments; Default Digital I/O Definitions - Vision VA61 User's Reference Manual

Gige camera vision appliance
Table of Contents

Advertisement

405-00022-00
The default configuration is 2 independent triggers, and strobe outputs disabled. You can change
these settings in the VA-Genie Camera Setup utility.
Sherlock Digital I/O
output Channel 0 (Strobe 1)
output Channel 1
output Channel 2
output Channel 3
output Channel 4 (Strobe 2)
output Channel 5
output Channel 6
output Channel 7
output Channel 8
output Channel 9
output Channel 10
output Channel 11
output Channel 12
output Channel 13
input Channel 0 (Trigger 1)
input Channel 1
input Channel 2
input Channel 3
input Channel 4 (Trigger 2)
input Channel 5
input Channel 6
input Channel 7
To trigger both cameras off one trigger input in Sherlock 7, you can use one of the GIO configura-
tion files included on the VA61.
NOTE
Sherlock does not give an error indication if you enable the strobes, and then
later write to one of the strobe output channels from Sherlock.
NOTE
If the Genie camera outputs are defined as "Open" or "Close" (default) they
appear in Sherlock's I/O, and change the output channel numbers.
Rev 06; 7 April 2011
SHERLOCK DIGITAL I/O ASSIGNMENTS

Default Digital I/O Definitions

Direction
out
out
out
out
out
out
out
out
out
out
out
out
out
out
in
in
in
in
in
in
in
in
Name
I/O Connector Pin
GPO0
7
GPO1
20
GPO2
8
GPO3
21
GPO4
9
GPO5
22
GPO6
10
GPO7
23
LED0 (amber)
LED1 (amber)
LED2 (amber)
LED3 (red)
LED4 (yellow)
LED5 (green)
GPI0
2
GPI1
15
GPI2
3
GPI3
16
GPI4
4
GPI5
17
GPI6
5
GPI7
18
VA6x User's Reference
APPENDIX C
41