Trigger and Strobe

1. Click on the "I/O Controls" tab (Figure 30).
2. Change the value beside "Trigger" to "True" to enable the external trigger mode.
Sherlock always uses triggered mode. This setting will be overwritten by Sherlock if you select
FALSE (FALSE is free-running).
Genie cameras have 2 inputs and 2 outputs on the 12-pin Hirose connector, that can be used as
camera trigger input, strobe output, and general purpose I/O.
3. Select Input 2 as the Trigger Source, if the trigger is coming from the 15-pin connector on
the VA61. You can use either Input 1 or Input 2 if you are triggering the camera directly (not
through the VA61 connectors), or through the DCI-100 connectors.