Installing Output Modules; Connecting A Printer - Menvier Security TS700 Installation & Programming Instructions

Intruder alarm control panel
Table of Contents

Advertisement

System Installation

Installing Output Modules

Output modules (CPA6.OM) can be used to provide an output to a set of LEDs to indicate circuit
activations (mimic). Output modules will normally be fitted inside the equipment they are
controlling and can be positioned up to 500 metres away from the main panel. They may be fitted
inside the TS700 by fitting posts and securing them to the base. The output module should be used
and connected in accordance with the output module instructions provided (Figure 8).
Connect to plug
labelled OUTPUT
MODULE
Figure 8. Output Module Connections

Connecting a Printer

The printer model type CPA6.P (obsolete) may be directly plugged on to the control panel plug
labelled PRINTER. Alternatively other models such as the DATAC or any standard RS232 serial printer
can be connected to the control panel via a MPA/DCI. Menvier Security supply a DATAC printer kit
which consists of a portable RS323 printer, charger and DCI. The DCI can be purchased separately
if you require to source your own RS232 printer.
Connect to JP1
PRINTER
Connect to JP1
PRINTER
Figure 9. Datac Printer Set-up and Connections
12
100m
PL1
CPA6 Printer
RS232 Data
MPA
or DCI
DATAC or RS232 printer
PL2
To next OM
1 2 3 4
5 6 7 8
TS700 Installation Manual
1k Resistors
LED's
PRINTER SETUP
Baud Rate
= 4800
Parity
= None
Stop Bits
= 2
Data Bits
= 8
DTR
= Normal