Programmable Outputs - Menvier Security TS700 Installation & Programming Instructions

Intruder alarm control panel
Table of Contents

Advertisement

TS700 Installation Manual

Programmable Outputs

The TS700 has many programmable outputs which can be used to drive relays, LED's etc. Each
output can be programmed for a different function, see "Programmable Output Types" on page
17.
Control Panel Outputs
The control panel has four high current programmable outputs:
[-1]
[-2]
[+3]
[+4]
Remote keypads & LEC Outputs
Each remote keypad and TS700 LEC has one programmable output:
[O/P]
+ve O/P
(Programmed as Alarm / Bell / etc)
Aux 0V
+ve O/P
(Programmed as Detector Reset)
Aux 0V
+ve O/P
Aux 0V
+ve O/P
Aux 0V
+ve Outputs
Figure 10. Programmable Outputs Wiring Examples
Set of voltage free changeover contacts rated at 1 Amp.
-
Switched -ve output rated at 500mA.
-
Switched +ve output rated at 500mA.
-
Switched +ve output rated at 500mA.
-
Switched -ve output rated at 100mA.
-
Relay available from
Diode (IN418)
RS components
P/No. 346-946.
Relay
Capable of switching
mains voltages
+ 12 V
0V
Smoke
Detector
1K0 Ohm Resistor
LED (Light Emiting Diode)
12V Buzzer
RS Part No. 245-051
Aux 12 V
-ve O/P
(Programmed as Alarm / Bell / etc)
Aux 12V
-Ve O/P
(Programmed as Detector Reset)
Aux 12V
-Ve O/P
Aux 12V
-Ve O/P
-ve Outputs
System Installation
Relay available from
Diode (IN418)
RS components
P/No. 346-946.
Relay
Capable of switching
mains voltages
+ 12 V
0V
Smoke
Detector
1K0 Ohm Resistor
LED (Light Emiting Diode)
12V Buzzer
RS Part No. 245-051
13

Hide quick links:

Advertisement

Table of Contents
loading