AA
Action Alarm (Alarm output activated)
Ac**
Access Passcode (User code **entered
with the last two digits reversed)
AD.**
Alarm Delayed (the system is part set and
circuit ** was activated)
Au.**
A u x i l i a r y
**activated)
BF
Battery Fault (battery voltage below 10.5V) PF
BT
Bell Test
CA.**
Circuit Alarm (from circuit number **)
cc
Communication Complete (Plug-on only)
cF
Communication Failed (plug-on only)
CI
Circuits Isolated (24 hour circuits)
CO.**
C i r c u i t s O m i t t e d ( c i r c u i t n u m b e r
**omitted)
Dc
Date Changed
DF
Default User code 1 to 5678
Du.**
Duress Alarm (from User code **)
EA.**
Entry Alarm (from circuit number **)
En.**
Entry (from circuit number **)
FA.**
Fire Alarm (from circuit number **)
FB.**
Fuse Blown (fuse number **)
Fn.**
First Knock (from circuit number **)
Fr
Factory Reset (LK1 closed on power up)
FS
Full Set
LB
Low Battery
LF
Telephone line fault
Lr
Telephone line restored
A l a r m
( c i r c u i t
n u m b e r
Table 7. Event Log Codes
LT
Lid Tamper or SAB tamper
OP
System Open (unset)
Or
Omits Removed
PA.**
PA Alarm (from circuit number **)
Power Failure (remote power LED flashes)
Pr
Power Restored
PS.*
Part Set (area *)
PT.**
Code Tamper (from remote keypad **)
rA
System re-armed
rc
System reset by REMOTE CODE RESET
rr.**
Remote Keypad ** removed
rT.**
Remote Keypad ** case tamper
SF
System Failed to Set
Sr
System on-site reset (LK1 open on power
up)
ST. *
Area * Set (using area setting codes)
So.**
Part set keyswitch ** operated
TA.**
Tamper Alarm (from circuit number **)
Tc
Time Changed
TF.**
Circuit ** failed test
To
All Test circuits removed from test
Un. *
Area * unset (using area setting codes)
Ur.**
User Code ** entered
--
No event