Fan Tray - Cisco Catalyst 6807-XL Hardware Installation Manual

Hide thumbs Also See for Catalyst 6807-XL:
Table of Contents

Advertisement

Fan Tray

• WS-X6848-SFP-2T and WS-X6848-SFP-2TXL
• WS-X6716-10T
• WS-X6816-10T-2T and WS-X6816-10T-2TXL
• WS-X6716-10G
• WS-X6816-10G-2T and WS-X6816-10G-2TXL
• WS-X6724-SFP
• WS-X6824-SFP-2T and WS-X6824-SFP-2TXL
• WS-X6904-40G-2T and WS-X6904-40G-2TXL
The switch supports the following Cisco Catalyst 6500 Series service modules:
• NAM3
• ASA-SM
• WiSM2
• ACE-30
For more information, see the
Related Topics
Installing Transceivers and Module Connectors, on page 47
Pluggable Transceivers, on page 79
Module Connectors, on page 84
Cable Specifications, on page 88
Fan Tray
The switch supports a single front-serviceable and hot-swappable fan tray with nine individual fans. The fan
tray is responsible for cooling the entire chassis and interfacing with environmental monitors to trigger alarms
when conditions exceed thresholds.
The fan tray supports:
• Model number C6807-XL-FAN.
• A maximum cooling capacity of 850 CFM
• Four variable-speed operating modes between 3,000 and 6,000 RPM
• Up to three fan failures. The fans that are working increase RPM or CFM.
• Online Insertion and Removal (OIR) for a minimum of 120 seconds (depending on the ambient
1 Cubic feet per minute.
2 Revolutions per minute.
Cisco Catalyst 6807-XL Switch Hardware Installation Guide
4
Catalyst 6500 Ethernet Module Installation
seven 800 W modules.
temperature).
Guide.
1
(120 CFM per slot). At this capacity, the fan tray can cool
2
Product Overview
for each fan.
OL-30656-01