General Display Specifications
Size Reference
Display Polarizer Type
Display Adjustment
Backlight
Backlighting Operation Options
Control Panel Mounted InfoAlarm Command Center Current Requirements
Master Controllers
(4100-9114, -9115,
-9116, -9212, -9213, -9222)
Redundant CPUs
(4100-9122, -9222)
Network Display Units, Non-Voice
(4100-9151, -9153, -9154, -9243, -9245)
Network Display Units, Voice
(4100-9152, -9155, -9156, -9244, -9246)
4100-7153 & -7155 for 4100U
Upgrade Kits
4100-7154 & -7156 for Legacy 4100+
Remote Annunciators with InfoAlarm Command Center, Powered from Control Panel
Voltage
Current
Mounting Details; Stand-Alone Cabinet Models
4100U Capacity,
RUI Output
Wiring Requirements
Custom Point Detail Messages
Message Location Details
Number of Messages
Message Size
Environmental
Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, IDNet, MINIPLEX, InfoAlarm, and the Simplex logo are trademarks of
Tyco International Ltd. and its affiliates and are used under license. National Electrical Code and NFPA are trademarks of the National Fire Protection Association.
© 2007 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
Dot Matrix Size 320 x 240
Active Display
4.53" W x 3.4" H (115 mm x 86 mm), includes header, footer, and softkey
Area
area; 5.66" diagonal measurement (144 mm)
Characters Up to 854 characters total using standard ASCII character font
Designation QVGA; one quarter of standard VGA (Video Graphics Array) display
Transflective with rear backlight
Contrast adjustment is located on the controller module
White LEDs with intensity adjustment and selectable AC power fail operation;
intensity adjustment is located on the controller module
On continuously; Off with AC power fail until a switch is pushed; selectable
timeout without switch activity
Supervisory 447 mA @ 24 VDC
Alarm 542 mA @ 24 VDC; backlight and tone-alert on
Supervisory 782 mA @ 24 VDC
Alarm 964 mA @ 24 VDC; backlight and tone-alert on
Supervisory 492 mA @ 24 VDC
Alarm 547 mA @ 24 VDC; backlight and tone-alert on
Supervisory 912 mA @ 24 VDC
Alarm 989 mA @ 24 VDC; backlight and tone-alert on
add 82 mA supervisory; add 127 mA for alarm
add 235 mA supervisory; add 280 mA for alarm
19 to 33 VDC (24 VDC nominal), system supplied; requires separate wiring
Supervisory 186 mA @ 24 VDC
Alarm 214 mA @ 24 VDC; backlight and tone-alert on
See page 6 for reference illustration
RUI (Remote Unit Interface) external annunciator communications line SLC
Type
(signaling line circuit)
Up to 31 total remote RUI devices, including up to 10 InfoAlarm Command
Capacity
Center devices
4100U: InfoAlarm Command Center, Remote Annunciators, MINIPLEX
RUI Device
Transponders; 4603-9101 LCD Annunciator, 4602-9101 Status Command
Reference List
Unit (SCU), and 4602-9102 Remote Command Unit (RCU); refer to data
sheet S4100-0031 for additional 4100U RUI information
Data Single twisted, shielded pair, 18 AWG (0.82 mm
Power 18 to 12 AWG (0.82 mm
A dedicated earth ground connection to the electrical box is required for
Earth
proper ESD and EMI protection; wire in accordance with NFPA 70 (National
Electrical Code
Select "more info" softkey when investigating point detail and scroll to the
bottom of the information; typical messages might include contact details
(phone numbers, pager numbers, etc.) and other contact or reference
information
Up to 50
120 characters; visible characters = 116; (lines 1 and 2 require one carriage
Character Details
return character and one line feed character)
3 lines total; 40 characters maximum per line; line 3 may be limited to 36
Line Details
visible characters depending on characters in lines 1 and 2
Operating Temperature 32° to 120°F (0° to 49° C)
Operating Humidity Up to 93% RH, non-condensing @ 90° F (32° C) maximum
Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA
www.tycosafetyproducts-usa-wm.com
2
2
to 3.31 mm
) wires for 24 VDC system power
®
) Article 250
Panel currents only
are shown, add
external device
loading per system
requirements
2
)
S4100-0045-4 11/2007

Advertisement

loading

This manual is also suitable for:

4100-93144100-93154100-95134100-93164100-95124100-9352 ... Show all