Product Selection
4100U Master Controller with InfoAlarm Command Center
Basic Control Panel details, standard product features, options, and reference for related fire alarm control panel products)
Model
Model Type
UL
4100-9114 English
4100-9115 English
4100-9116 French
4100-9213 International
4100-9212 International
4100-9122 English
4100-9222 International
Upgrade Kits
(see NOTE for NDU upgrades; Upgrade kit are UL and ULC listed)
Model
Model Type Description
Upgrade Kit for existing 4100U Series Fire Alarm Control Panels; includes complete
4100-7153
English
bay front assembly with InfoAlarm Command Center providing raised keys with fixed
labels; uses existing power supply and Master Controller Board (CPU card)
Upgrade Kit for existing 4100 (Legacy 1000 pt, 4100+ systems) Series Fire Alarm
Control Panels (non-4100U); includes complete bay front assembly with InfoAlarm
4100-7154
English
Command Center; raised keys with fixed labels, and replacement Master Controller
Board; uses existing power supply
Upgrade Kit for existing 4100U Series Fire Alarm Control Panels; includes complete
bay front assembly with InfoAlarm Command Center providing flat keys with inserts for
4100-7155 International
custom key labels; use for non-English language applications including French for
Canada; uses existing power supply and Master Controller Board (CPU card)
Upgrade Kit for existing 4100 (Legacy 1000 pt, 4100+ systems) Series Fire Alarm
Control Panels (non-4100U); includes complete bay front assembly with InfoAlarm
4100-7156 International
Command Center; flat keys with inserts for custom key labels, and replacement Master
Controller Board; use for Canadian French applications; uses existing power supply
Extended Memory CPU, required to upgrade NDU to InfoAlarm Command Center; included with InfoAlarm
*4100-7157
Command Center NDU models below; (single language NDU supports 12,000 points, bilingual NDU supports 9000 pts)
Network Display Unit (NDU) Master Controller with InfoAlarm Command Center
(NOTE: See data sheet S4100-0036 for NDU feature details and for details on SPS NAC ratings for NDU with VCC)
Model
Model Type
UL
4100-9151 English
4100-9153 English
4100-9154 French
4100-9245 International
4100-9243 International
4100-9152 English
4100-9155 English
4100-9156 French
4100-9246 International
4100-9244 International
Remote Annunciator with InfoAlarm Command Center
Model
Model Type
UL
4100-9612 English
4100-9613 French
4100-9614 International
4100-9607 English
4100-9608 French
4100-9609 International
InfoAlarm Command Center Memory Option
Model
Description
Display Memory Expansion Module; included with NDU systems; required for all InfoAlarm Command Centers
*4100-0640
connected to a panel if any are using 2 byte character fonts; 6 Meg module mounts on rear of display board
(continued on next page)
ULC Voltage
—
120 VAC, 60 Hz
—
—
120 VAC, 60 Hz
220/240 VAC,
—
50/60 Hz
—
120 VAC, 60 Hz
220/240 VAC,
—
50/60 Hz
ULC Voltage
—
120 VAC, 60 Hz
—
—
120 VAC, 60 Hz
—
220/240 VAC, 50/60 Hz
—
120 VAC, 60 Hz
—
—
120 VAC, 60 Hz
220/240 VAC, 50/60 Hz
—
ULC InfoAlarm Command Center Type
With raised keys and fixed labels
—
With flat keys & inserts for custom key labels
—
With raised keys and fixed labels
—
—
With flat keys & inserts for custom key labels
(may be required to be ordered separately, see description details)
(see data sheet S4100-0031 for descriptions of the 4100U
InfoAlarm Command Center Type
Master Controller Assembly; raised keys
with fixed labels
Master Controller Assembly; flat keys
with inserts for custom key labels
Redundant CPU (Master Controller);
raised keys with fixed labels
Redundant CPU (Master Controller); flat
keys with inserts for custom key labels
NDU Type
NDU (Standard, Non-Voice);
raised keys with fixed labels
NDU (Standard, Non-Voice);
flat keys with inserts for
custom key labels
NDU with Voice Interface
and Control; raised keys
with fixed labels
NDU with Voice Interface
and Control; flat keys with
inserts for custom key labels
(see data sheet S4100-0038 for Remote Annunciator features)
Basic
Remote
Annunciator
Remote
Annunciator
6
Master Controller Features
9 A system power
supply/battery charger (SPS),
250 point IDNet interface,
3 NACs, auxiliary relay, and
external RUI communications
interface
One Command Center, two
CPU cards, and an SPS in a
two bay assembly; NOTE: For
external RUI, use 4100-1291
RUI Expansion module(s)
NOTE*
NDU
upgrades
require:
4100-7157*
Extended
Memory CPU
and
4100-0640*
Display
Memory
Expansion
Master Controller Features
Includes: 4100-7157 Ext. Memory
CPU, 4100-0640 InfoAlarm Memory
Expansion, Network Interface Module
(select media cards separately), 9 A
SPS power supply/batt. charger, and
external RUI; (NOTE: SPS IDNet™
channel and NACs are disabled)
Includes above features and adds:
VCC Bay with Standard CPU Module,
Network Interface Module (select
media cards separately), 9 A SPS with
250 Point IDNet Interface, (3) 3 A
NACs, and ext. RUI comm. interface
Master Controller Features
Includes Expansion Bay with
PDI, Remote TIC module;
power is supplied from host
control panel
Includes Expansion Bay with
PDI, Remote TIC module;
power supply is specified
separately when configured
S4100-0045-4 11/2007
Need help?
Do you have a question about the 4100U and is the answer not in the manual?