Product Selection - Simplex 4100ES Operating Instructions Manual

Fire control panels. remote annunciator panels
Hide thumbs Also See for 4100ES:
Table of Contents

Advertisement

Product Selection

Panel Type
Model
Description
Remote Annunciator Panel; requires an internal
4100-9610
power supply
Basic Remote Annunciator Panel; requires
4100-9611
power from another cabinet (refer to module
exclusion list on page 2)
Remote Command Center Option
S4100-0045)
Model
Description
Panel Mounted LCD Annunciator; 2 line by 40
character LCD with LED illumination; LED
4100-1292
illumination is off during supervisory, turning on
with alarm or when switches are activated
Emergency Voice/Alarm Communications Operator Interface Options
Model
Description
4100-1244
Remote Microphone (mike) Module
4100-1252
1 Channel (audio or mike)
4100-1253
1.5 Channel (audio + mike)
4100-1254
2 Channel (full audio)
4100-1255
3-8 Channel
Firefighter Telephone System Products (refer to document S4100-0034 for additional detail)
Model
Description
4100-1271
Remote Master Telephone
4100-1272
Phone Module with 3 Class B phone NACs
4100-1273
Phone Class A Adapter Module
LED and LED/Switch Modules, General Purpose (LED/switch controller and label kit is ordered separately)*
LEDs per Switch
LEDs
One
8
Two
16
Two
16
One
16
LEDs per Switch
LEDs
LEDs only
8
LEDs only
16
One
16
One
24
LED/Switch Modules, Special Purpose
Model
Operation
Eight function HOA (On, Off, Auto) Control Module
4100-1286
with labeled switches
4100-1295
Eight function HOA (On, Off, Auto) Control Module, same as 4100-1286 except switches are unlabeled
LED/Switch Controller Modules and Accessories
Model
Description
64 LED/64 Switch Controller Module with mounting plate; controls up to 64 LEDs and
4100-1288
interfaces to up to 64 switches; mounts behind the LED/switch modules and has
provisions for one 4100-1289 Controller Module
64 LED/64 Switch Controller Module without mounting plate; mounts on extra space of
4100-1289
4100-1288; controls an additional 64 LEDs and 64 switches
4100-1294
LED/Switch Module Slide-in Labels, required when LED/switch modules are present; order one per cabinet
24 Point I/O Module for external connections, select each point as either input or output; 2" (51 mm) wide, 1 Slot; refer to
4100-1290
S4100-0032 for more detail; not available with 4100-9611
* Note: Refer to data sheet S4100-0032 for additional LED/Switch module selections.
(for InfoAlarm Command Center expanded content display products, refer to data sheet
Operator
Interface
Modules
Switches
Model
LED Color(s)
8
4100-1280
Red
8
4100-1282
Red on top, Yellow on bottom
8
4100-1284
Red on top, Green on bottom
16
4100-1285
Red
Switches
Model
LED Color(s)
LEDs only
4100-1276
Red, pluggable
4100-1277
LEDs only
Pluggable LEDs, shipped Red on top, Yellow on bottom
Pluggable LEDs, shipped Red on top, Yellow on bottom;
16
4100-1300
Note: UL, ULC, and CSFM listed only
24
4100-1287
Red
(LED/switch controller, label kit, and separate LEDs are ordered separately)
(LED kits for 4100-1276/1277/1300 are on page 4)
Details and Mounting Reference
Includes a bay assembly with power distribution board, a Basic
Transponder Interface Module (4100-0620) mounted in Block A, and an
interconnect harness for connecting to 4100ES/4100U Slot modules
Supervisory and Alarm current = 87 mA
Includes a bay assembly with power distribution board, a remotely powered
Transponder Interface Module mounted in Block A, and an interconnect
harness for connecting to 4100ES/4100U Slot modules
Supervisory and Alarm current = 87 mA
Details and Mounting Reference
Mounting requires the top bay; 4100ES/4100U flat modules are allowed
behind it; RUI device, RUI/RUI+ connection is required
Supervisory current = 65 mA (w/o backlight)
Alarm current = 140 mA
Details and Mounting Reference
Front panel module; requires 2 Slots (4" [51 mm]), space behind accepts
4100ES/4100U flat modules only (requires dedicated wiring to fire alarm
control panel audio control module); Supv. = 2.4 mA, Active = 6 mA
Single slot modules requiring connection to an LED/switch controller; space
behind accepts 4100ES/4100U flat modules only; adjacent LED/switch
module(s) are required for specific speaker circuit selection (refer to
document S4100-0034 for audio reference and document S4100-0032 for
LED/switch module reference); Supv. = 0, Alarm = 24 mA
Details and Mounting Reference
Mounts in two vertical blocks of bay front, locate as required; space behind
allows 4100ES/4100U flat modules only
Single Block module, mounts to bay mounting plate
Mounts to 4100-1272, no additional space required
Model
4100-1281
4100-1283
4100-1296
4100-1278
Switch Function (Location)
On (top)
Off (middle)
Auto (bottom)
3
Not available
with 4100-9611
LED Color(s)
Yellow
Yellow, top and bottom
Green on top, Yellow on bottom
8 Red on left, 8 Yellow on right
*
LED Description
Green LED
Red LED
Green LED
*
NOTE: LED/switch controllers and
their connected LED/switch
modules must be in the same bay;
(see data sheet S4100-0032 for
details)
(continued)
S4100-0038-14 5/2018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents