Product Selection - Simplex TrueAlarm 4100 Series Manual

Fire alarm control and indicating equipment
Table of Contents

Advertisement

Product Selection

System Type
(select 4100 prefix for stand-alone systems, 4120 prefix for networked systems)
4100/4120-
8001
Basic Fire Control Panel
8010
Miniplex Control Panel
8201
Control Panel with Audio
8210
Miniplex Control Panel with Audio
8019
Miniplex Transponder
Master Controller Option
4100/4120-
EN54 Master
4100-7014
Controller
Assembly with
4120-7014
Display
System Requirements
4100/4120-
6027
CE Mark Option
6081
Version 8 Software
6051
Non Power-limited
Conventional Zone Circuits
4100/4120-
5004
8 Zone Class B
Sounder and Speaker Circuits
4100/4120-
4001
Two Circuit Class B
4205
Dual Circuit, Triple Channel Class B
4321
Six Circuit Class B
Auxiliary Relay Control
4100/4120-
3001
Four Relays, 2A with Feedback
3002
Four Relays, 10A with Feedback
3003
Eight Relays, 3A with Feedback
Power Supply Options
4100/4120-
8 A Intelligent Power Supply with
0157
Charger, 230 VAC
0158
8 A Power Supply, 230 VAC
Temperature Compensated Battery
0164
Charger, 230 VAC
Interface Options
4100/4120-
0110
MAPNET II Addressable Zone Module
0113
Dual RS232 Module
0304
Remote Unit Interface (RUI)
Audio Controller Board Options
4100/4120-
0210
Single Channel Operation
0211
Dual Channel Operation
0212
Triple Channel Operation
(1) LPC (Loss Prevention Council) Approval pending for 4100 model series (PIDs) only. (2) LPC Approval pending.
(3) Tested by LPC to verify that no detrimental effect occurred to mandatory EN54 functions.
Module size: "Internal" = only occupies space behind retainer panel.
"Retainer" = only occupies space at retainer panel level and internal modules can be located behind.
Module Size Reference: Each unit of space has 16" (406 mm) of panel width available. (8" = 203 mm, 4" = 102 mm, 2" = 51 mm)
Simplex Time Recorder Co.
(LPC approval status designated per model number, see legend below)
Description
Description
Standard
For 4120 Network
Description
Description
Description
Description
Description
Description
Description
LPC Status
Quantity
Choose
(1)
One
LPC Status
Quantity
(2)
Choose
One
N.A.
LPC Status
Quantity
(2)
Required
LPC Status
Quantity
(2)
As Required
LPC Status
Quantity
(2)
As Required
LPC Status
Quantity
N.A.
As Required
(2)
LPC Status
Quantity
(2)
As Required
LPC Status
Quantity
(2)
As Required
LPC Status
Quantity
Choose One as
(3)
Required
6
Standby
Alarm
Module Size
See below
Standby
Alarm
Module Size
8" Internal
16" Retainer
625 mA
675 mA
10" Internal
16" Retainer
Standby
Alarm
Module Size
Not applicable
Standby
Alarm
Module Size
75 mA
195 mA
2" Internal
Standby
Alarm
Module Size
16 mA
33 mA
25 mA
80 mA
2" Internal
25 mA
70 mA
Standby
Alarm
Module Size
15 mA
75 mA
2" Internal
15 mA
175 mA
4" Internal
25 mA
280 mA
2" Internal
Standby
Alarm
Module Size
––
––
6" Internal
––
––
4" Internal
––
––
Standby
Alarm
Module Size
470 mA
490 mA
4" Internal
132 mA
132 mA
2" Internal
85 mA
85 mA
Standby
Alarm
Module Size
185 mA
185 mA
220 mA
220 mA
12" Internal
220 mA
220 mA
S4100-0025 (EN54) 5/99