DOOR OPENER STATE
OPEN
CLOSE
OPENING
CLOSING
DOOR TRAVEL STOPPED
DOOR OBSTRUCTED WHEN OPENING
DOOR OBSTRUCTED WHEN CLOSING
OPENER OVERLOADED
DOOR IN OPEN POSITION WITH
AUTO CLOSE MODE SELECTED
MAINS POWER INTERRUPTED
BUTTON
Operate
Door Code
Light Code
Door Code & Minus (-)
Light Code & Minus (-)
Force Margin Set & Pus (+)
Force Margin Set & Minus (-)
Force Margin Set (then) Set
Auto Close Time (then) Plus (+)
Auto Close Time (then) Minus (-)
Auto Close Time (then) Set
Force Margin Set & Auto Close Time (then) Plus (+)
Force Margin Set & Auto Close Time (then) Minus (-)
Force Margin Set & Auto Close Time (then) Set
Minus (-) (for 6 secs.)
Set & Close (for 2 secs.)
Set (the power on) and hold until all LEDs are off
Door Code (the power on) and hold until all LEDs are off
Set & Door Code (the power on) and hold until all LEDs are off
Set
PARAMETERS

DOOR STATUS INDICATORS

OPEN LED GREEN
ON
FLASHING
FLASHING
FLASHING
ALTERNATING
FLASHES
ONE SECOND
FLASHES
RAPID
FLASHES
FUNCTION
Opens/Stops/Closes the door
Codes a transmitter button for Operate function
Codes a transmitter button for light function
Codes a transmitter button for pet (pedestrian) function
Codes a transmitter button for vacation function
Increases the obstruction force margin setting
Decreases the obstruction force margin setting
Reloads the factory set default obstruction force margin setting
Increases the auto close delay time
Decreases the auto close delay time
Reloads the factory set default auto close delay time
Each press of the open button increases the light time by 10 secs.
Each press of the open button decreases the light time by 10 secs.
Reloads the factory set default light time
Clears the door limits set positions. Limits then need to be reset.
Enters pet (pedestrian) position mode.
Deletes control parameters excluding transmitter storage memory.
Deletes all transmitter storage memory.
Deletes all control parameters and transmitter storage memory.
Re initialises opener obstruction force margin.
24
CLOSE LED
DOOR STATUS
RED
LED YELLOW
ON
FLASHING
FLASHING
FLASHING
ALTERNATING
FLASHES
BEEPER
BEEPS WHILE
DOOR IS MOVING

Hide quick links: