Yamaha XT660R S Service Manual page 443

Hide thumbs Also See for XT660R S:
Table of Contents

Advertisement

4. Voltage
• Connect the pocket tester (DC 20 V) to the
immobilizer unit coupler as shown.
Positive tester probe → red/white 1
Negative tester probe → black 2
2
B BB
R/G
Y/L G/L R/W
1
• Set the main switch to "ON".
• Measure the voltage (12 V) between red/
white and black on the immobilizer unit
coupler.
• Is the voltage within specification?
YES
IMMOBILIZER SYSTEM
R/G B2
B
R/W Lg Y/L
NO
The
wiring
circuit
from the main switch
to
the
immobilizer
unit is faulty and
must be repaired.
http://manuals.magnamaniac.com
5. Voltage
• Connect the pocket tester (DC 20 V) to the
immobilizer unit coupler as shown.
Positive tester probe → green/blue 1
Negative tester probe → black 2
2
B BB
Y/L G/L R/W
• Set the main switch to "ON".
• Measure the voltage (2.6 V) between
green/blue and black on the immobilizer
unit coupler.
• Is the voltage within specification?
The
wiring
from the immobilizer
unit to the meter
assembly
is
and
must
repaired.
8 - 60
ELEC
R/G
R/G B2
R/W Lg Y/L
1
YES
circuit
Replace the immobi-
lizer unit.
faulty
be
+
B
NO

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xt660x s2004 xt660r(s)2004 xt660x(s)Xt660 2004Xt660r 2004Xt660rs 2004 ... Show all

Table of Contents