CHECKING AND CHARGING THE BATTERY
Charging method using a variable-current (voltage) charger
Charger
YES
Adjust the voltage to obtain the
standard charging amperage.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to "CHECKING AND
CHARGING THE BATTERY".
If the required charging time exceeds 5 hours, it is advisable to check the
charging amperage after 5 hours. If there is any change in the amperage,
readjust the voltage to obtain the standard charging amperage.
Leave the battery unused for more than 30 minutes before measuring its
open-circuit voltage.
12.8 V → Charging is complete.
12.0 ~ 12.7 V → Recharging is required.
Under 12.0 V → Replace the battery.
Measure the open-circuit
voltage prior to charging.
Ammeter
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
3 - 59
TIP:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
TIP:
Set the charging voltage to 16 ~
17 V. (If the charging voltage is
lower, charging will be insufficient,
if it is higher, the battery will be
over-charged.)
Adjust the charging voltage to
20 ~ 25 V.
Monitor
YES
3 ~ 5 minutes. Is the standard
charging amperage exceeded?
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
CHK
ADJ
NO
the
amperage
for
NO

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rhino 700 2008Rhino 700fi 2008Rhino yxr70fx 2008

Table of Contents