Optional Equipment
Extra Room Power Heat Duct
Special Instructions for 864 ST
The 864 ST has a removable cover plate shield below the heat duct connections. This allows
more heat to be routed to the power heat ducts (see below for details). Otherwise the heat duct is
installed the same as an 864TRV (one heat duct kit maximum, manually-controlled on/off
operation – see wiring diagram below).
Power Heat Duct Wiring Diagram
Power Heat Duct Wiring Diagram
• 864 TRV
• 864 ST
• 864 HH
(sn 3407-001009 or less)
-Remove the Heat Shield Cover Plate
Remove and discard the power heat
duct cover plate.
Travis Industries
(for qualified installers only)
(sku 98500769)
Rheostat
Junction Box
Hot
Hot
(black)
(black)
Common
Common
(white)
(white)
Ground
Ground
(green)
(green)
Remove and discard the circular cover
plate attached to the heat shield.
4071126
Blower
Assembly
NOTE: an additional power heat
duct hook-up location is provided
on the right side (it is along the top
edge of the fireplace).
NOTE: Only one hook-up may be
used (do not hook up two heat
ducts to the fireplace).
100-01195_000