Finalizing the Installation

Approved Vent

Side vent configurations use 8" diameter Simpson Dura-Vent Model Pro or GS vent.
Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Model Pro or GS vent. If
using 6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) to the
fireplace.

Vent Installation

Slide the vent sections together and turn 1/4 turn until the sections lock
in place.
Screws are not required to secure the vent. However, three screws may
be used to secure vent sections together if desired.
High temperature sealant is recommended at the appliance starter
section connection (use high-temperature silicone or Mill-Pac®).
If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the
joints of the affected sections.
Horizontal sections require a 1/4" rise every 12" of travel.
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape).
© Travis Industries
6-5/8" Diameter Vent
Reducer - # 98900165
4071126
(for qualified installers only)
19