Finalizing the Installation
Side Vent Configuration with Horizontal Termination (with vertical rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
and diffuser positions.
Up to four elbows (45° or 90°) may be used.
Only one horizontal elbow may be used.
22' (max)
20 feet
15 feet
10 feet
5 feet
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
(for qualified installers only)
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2 (stock)
Exhaust Restrictor # 4
Intake Restrictor # 1
Diffuser Position # 1
Exhaust Restrictor # 2 (stock)
Intake Restrictor # 1 (stock)
Diffuser Position # 1
H2
H1
4071126
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
22' (max)
20 feet
15 feet
10 feet
5 feet
0 feet
100-01195_000