Optional Equipment
6
Remove the
regulator from the
front of the gas
control valve.
Replace with the
propane regulator,
using the new
gasket and screws
included with the
regulator. NOTE:
Leak test this
area after the
heater is
installed, gas is
connected, and
the main burner is
lit.
7
Make the gas line
connection, bleed
the gas line (if
applicable), start
the heater and
thoroughly leak-
test all gas
connections and
the gas control
valve. Check the
pilot (see the
illustration below.
Adjust if
necessary.
WARNING:
When lighting or re-
lighting the pilot, the
glass must be removed
(see page 40).
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
© Travis Industries
(for qualified installers only)
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
Standard
Screwdriver
4071126
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Place the LP
label on the base
of the fireplace
near the gas
control valve.
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
55
d
100-01195_000