20
Finalizing the Installation

Approved Vent Configurations

Restrictor Position

Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and
exhaust gases. Depending upon the vent configuration, you may be required to adjust the
restrictor positions. The charts for acceptable vent configurations detail the correct vent
restrictor positions.

Exhaust Restrictor Adjustment

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust
restrictor is removed (see page 22).
Travis Industries
(closed) #6
# 5
# 4
# 3
# 2
(open - stock position) # 1
4071126
(for qualified installers only)
Loosen these two screws
on the exhaust restrictor.
Slide the restrictor to the correct
restrictor position (see the illustration
below). The screw location indicates
restrictor position. In this example, the
restrictor is set in position # 3. Tighten
the screws to secure the restrictor.
Left (vent) Side of Firebox