Extra Room Power Heat Duct - Travis Industries 864 HH Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for 864 HH:
Table of Contents

Advertisement

Optional Equipment

Extra Room Power Heat Duct

Special Instructions for 864 HH
Newer 864 HH fireplaces (SN 3407-001010 or later) have an improved wiring harness and
removable heat shields below the heat duct connections. The wiring harness is now routed through
the snap disk, allowing the power heat duct to be turned on and off by the fireplace (see "Wiring
Instructions" on page 62). An additional knock-out was added to the fireplace to allow for the
electrical line to be routed to the power heat duct (see below). The removable heat shields allow
more heat to be routed to the power heat ducts (see below for details).
New Wire Hook-Up
A knock-out is provided on the left side of the fireplace for
routing the sheathed cable (romex) from the inside of the
firebox to the power heat duct. Use the strain relief
(included with the power heat duct) to secure the cable.
Cable to
Power Heat
Duct
New Removable Heat Shield (improves heat output to power heat duct)
Remove and discard the power heat
duct cover plate (one or both sides).
© Travis Industries
(for qualified installers only)
(sku 98500769)
Molex Connector
(attached to the
wiring harness on
the fireplace)
Molex Connector (included with heat duct
kit) - use wire nuts to attach to the cable.
4080214
Remove and discard the circular cover
plate attached to the heat shield.