Rear Vent Config. W Horizontal Term. (No Vertical Rise); Rear Vent Configuration With Horizontal Termination (No Vertical Rise) - Travis Industries GreenSmart 564 SS Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for GreenSmart 564 SS:
Table of Contents

Advertisement

26

Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45° Elbow
Vent with No 45° Elbow
3 feet
915mm
0 feet
Vent with 1 45° Elbow
3 feet
915mm
0 feet
Travis Industries
Installation
See the charts below to
determine maximum vent
mm
mm
(for qualified installers only)
Termination
• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1.2m) Horizontal Section(s)
• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal Section(s)
4090709
100-01222_000