CHAPTER 11 SYSTEM INTEGRATION
C. Hardware
The following shows the connectors, LED, ROMs, and fuse used on the board:
IC112S
(4MB PROM)
CPU
LED101
Fu101
(SCSI)
Item
J8501
Used it for connection to the system motherboard.
J8502/J8503
Use it to connect the host computer/terminator (shared).
Fu 101
Use it to prevent overcurrent to the SCSI PCB. E603 will be indicated when Fu101
blows.
LED 101
<LED is On or Off>
The CPU on the SCSI PCB is not operating (faulty PCB). E601 is indicated on the
control panel.
<LED is Flashing (on for 0.2 sec; remains off longer)>
The CPU on the SCSI PCB is operating, but the cable connection is poor or the PCB is
faulty. E601 is indicated on the control panel.
<LED is Flashing (off and on at intervals of 0.5 sec)>
The operation is normal.
IC112S
Used for SCSI.
11-6
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
J8501
System motherboard
J8503
(SCSI-2)
(SCSI-2)
Image memory
(DRAM 10MB)
Figure 11-202
Description
Table 11-202
J8502

Hide quick links: