CHAPTER 9 FIXING SYSTEM
3. Removing the Fixing Roller
1) Remove the fixing assembly from the
copier.
2) Remove the two screws [1], and detach
the fixing cleaner assembly [2].
[2]
[1]
Figure 9-212
3) Remove the fixing heater.
4) Shift the paper guide [3] to the left to
detach.
[3]
Figure 9-213
5) Remove the four screws [6], and detach
the thermal switch assembly [4] and the
thermistor assembly [5].
[6]
[4]
Figure 9-214
9-18
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[6]
[5]
6) Remove the three screws [8] and another
screw [9] (M3x6); then, detach the
harness guide [7].
[9]
[8]
[7]
Figure 9-215
7) Remove the two screws [11], an detach
the heater guide plate.
[10]
[11]
[11]
Figure 9-216