A. CCD Unit
1. Removing the CCD Unit
1) Disconnect the power plug.
2) Remove the copyboard glass.
3) Remove the six screws, and detach the
CCD unit cover [1].
[1]
Figure 4-400
4) Remove the screw, and detach the original
size sensor [2] to keep it away from the
CCD unit.
[2]
Figure 4-401
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[2]
[2]
CHAPTER 4 IMAGE FORMATION SYSTEM
5) Remove the grounding wire [3],
disconnect the two connectors [4], and
remove the cable [5].
6) Remove the screw (1 pc. each), and
detach the CCD unit stop spring [6]; then,
detach the CCD unit.
[5]
[6]
Figure 4-402
Caution:
Do not remove the screws that are pain-
locked in place.
Particularly, never remove the screws
[7] indicated in Figure 4-403.
[7]
[7]
Figure 4-403
[4]
[3]
[4]