NXB-AP-1000 Interface – Initial Setup by Network Admin

DoD Security Mode / ICSP Support

DoD Security Mode
The Epica DGX 32 is a matrix switcher that provides a DoD Security mode, which allows for BCS (Basic
Control Structure, AMX AutoPatch's ASCII command protocol) tunneling over IP.
Important: When DoD Security mode is "on" a BCS tunnel is available; however, the NXB-AP-1000
interface is unavailable.
To enable DoD Security mode for the Epica DGX 32:
1.
Insert one end of an RJ-45 cable into a network card on a PC.
2.
Insert the other end of the cable into the TCP/IP port on the enclosure.
3.
Open an SSH terminal emulator (e.g., PuTTY); connect to the IP address of the NXB-AP-1000.
SSH utilities require a username and password to login.
4.
Type set security profile.
A prompt will appear indicating the current setting and the options for the setting.
5.
To enable DoD Security mode, type 2 and press enter.
You will be prompted to reboot the system for the new setting to take effect.
6.
Type reboot and press enter.
Important: When the system is in DoD Security mode, the user name automatically changes to
administrator and the password to Amx1234! The user name and password are case sensitive and
can be changed by connecting over SSH, entering security setup, and following the menus.
88
The three security profile settings are
described in the table on page 90.