Defining And Executing Global Presets - AMX Epica DGX 32 Instruction Manual

Distribution matrix
Hide thumbs Also See for Epica DGX 32:
Table of Contents

Advertisement

Defining and Executing Global Presets

Global presets are predefined sets of switches that can easily be executed at one time. A global preset
number can be assigned to a routing state during runtime and stored by the system, allowing you to
replicate an entire system state. (The system state includes any special settings and all signal routings.)
That system state can be restored at any time by selecting the assigned global preset number. Global
presets can be defined or recalled using either the Epica DGX 32 Control Panel or BCS commands
interchangeably. The Epica DGX 32 Control Panel supports up to 64 global presets.
Defining Global Presets
A global preset is a snapshot of an entire system's state which enables that system state to be recalled at
a later time. Before defining a global preset, the system must be routed to the desired state.
Because all 64 potential global preset numbers are displayed in the Global Preset submenu, be aware that
nothing indicates which of the numbers have been assigned a routing state.
Caution: We strongly recommend keeping track of the number and the system state routing used
for each global preset. If a previously used number is assigned to another system state (using either
the Epica DGX 32 Control Panel or BCS commands), the former state will be automatically
overwritten.
The example below defines Global Preset 3, and the example on the next page executes Global Preset 3.
Important: Wait approximately ten seconds for the system to permanently store the global preset
setting before executing another operation.
To define a global preset:
1.
Route the system to the desired state.
2.
Press the Function Key.
The Function menu appears.
3.
Locate Global Preset by scrolling with the Control Dial.
4.
Press the Select Key.
The Global Preset submenu appears.
5.
Scroll with the Control Dial to Define Global.
Press the Select Key.
The Define Global list appears.
Epica DGX 32 Instruction Manual
Control Panel Operation
63

Advertisement

Table of Contents
loading

Table of Contents