<Method name="PFDStop">
<Instructions>
<Send>PFD
</Instructions>
</Method>
</StreamDevice>
The symbols


command in the xml structure.
Finally the automationcues.xml file can be edited so that the MI-WAVE3D device is
associated with the command names that have been created. This allows the cues
to be seen in the Qube graphical interface.
Note: Again, this file is a shared file with other devices in the system so must be
edited and not replaced.
4. Edit this file so that it contains the information below:
<Cue name="Start 3D">
<Actions>
<InvokeMethod name="Start" device="MasterImage"/>
</Actions>
</Cue>
<Cue name="Stop 3D">
<Actions>
<InvokeMethod name="Stop" device="MasterImage"/>
</Actions>
</Cue>
<Cue name="3D Position">
<Actions>
<InvokeMethod name="3Dposition" device="MasterImage"/>
</Actions>
</Cue>
<Cue name="2D Position">
<Actions>
<InvokeMethod name="2Dposition" device="MasterImage"/>
</Actions>
</Cue>
<Cue name="Up/Down Stop">
<Actions>
<InvokeMethod name="PFDStop" device="MasterImage"/>
</Actions>
</Cue>
Stop
</Send>
are necessary at the end of each command to close the
© MASTERIMAGE 3D, Inc.
Installation & Operation Manual | MI-WAVE3D
48