Valor Quantum & Urban 746 Installer's Manual page 19

Inset live fuel effect gas fire
Hide thumbs Also See for Quantum & Urban 746:
Table of Contents

Advertisement

INSTALLER GUIDE
IMPORTANT
Before continuing with the
installation of this gas fire the
aeration setting on the burner
must be checked. The aeration is
factory set for use with a ceramic
pebble fuel effect. See section 17.1
(Servicing and parts
replacement).
Figure 9. Burner attachment points
4. It is important that the grommet
supplied in the loose parts pack is fitted to
the hole in the rear of the hotbox.
5. There is a length of self adhesive foam
seal supplied with the fire. This will need to
be fitted to the outer rear edges of the side
and top flanges of the hotbox. Cut the foam
seal to the required length. Be careful not to
stretch the seal when measuring. Remove
the protective backing from the foam seal
and fit this to the rear of the top flange (See
figure 10).
8.2 The Flue Restrictor
This appliance is supplied with a flue
restrictor for use where the flue draught is
excessive. The restrictor must not be fitted
where a precast flue or a 125mm flue liner
Figure 10. Fitting the foam seal
is used. For flue liners greater than 125mm
and all other installations the restrictor should be
fitted. There may however, be certain exceptional
circumstances where fitting the restrictor causes
the fire to fail the spillage test. In such cases the
restrictor will have to be removed. After removal
conduct the spillage check again.
The restrictor is packed flat with the appliance
and will require bending prior to fixing. Bend the
Figure 11. Bending the restrictor
restrictor as shown in figure 11.
Page 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quantum 746

Table of Contents