Chapter 6 Alternator/Electrical Equipment
STATOR INSTALLATION
Install the stator on the right crankcase cover
with the three bolts.
Install the ignition pulse generator and breather
plate with two bolts.
Install the wire grommet in its groove in the cover
securely.
NOTE
◦ Be sure to route the stator wire under the pulse
generator.
◦ Make sure that the breather plate is in position
securely.
RIGHT CRANKCASE COVER
INSTALLATION
Install the dowel pins and a new gasket.
Install the right crankcase cover over the
crankcase, aligning the water pump shaft groove
with the oil pump shaft.
Install the right crankcase cover attaching bolts
and tighten them.
Connect the crankcase breather tube to the right
crankcase cover
Connect the ignition pulse generator and
alternator wire couplers and connector.
Connect the water hoses to the water pump.
Make sure that the oil pipe is not clogged.
Install the oil pipe with oil bolts and sealing
washers.