Adjusting The Tension Of The Flip Up Footplate; Chairs Built Before 12/01/2008; Chairs Built After 12/01/2008 - Invacare Adjustable ASBA Seat Service Manual

Adult seats junior seat
Table of Contents

Advertisement

Adjusting the Tension of the Flip Up Footplate

Chairs built before 12/01/2008

NOTE: For this procedure, refer to 
FIGURE 5.7.
NOTE: The tension can be adjusted to increase 
or decrease the rotation effort of the flip up 
footplates.
1. Loosen the mounting screw on the 
footrest angle hinge to decrease the 
rotation effort.
NOTE: DO NOT remove the footplate 
mounting screw.
2. Tighten the mounting screw on the 
footrest angle hinge to increase the 
rotation effort.
3. Repeat STEPS 1 and 2 for the other 
footplate.

Chairs built after 12/01/2008

NOTE: For this procedure, refer to 
FIGURE 5.8.
NOTE: The tension can be adjusted to increase 
or decrease the rotation effort of the flip up 
footplates.
1. Loosen the mounting screw on the 
front rigging angle hinge to decrease 
the rotation effort.
NOTE: DO NOT remove the footplate 
mounting screw.
2. Tighten the front rigging angle hinge 
mounting screw to increase the rotation 
effort.
3. Repeat STEPS 1 and 2 for the other 
footplate
Part No 1143238
SECTION 5—CENTER MOUNT FOOTRESTS
Center
Mount
Footrest
Footrest
Angle Hinge
Mounting Screw
FIGURE 5.7 Adjusting the Tension of the
Flip Up Footplate -
Chairs built before 12/01/2008
Center Mount
Footrest
Mounting Screw
FIGURE 5.8 Adjusting the Tension of the
Flip Up Footplate -
Chairs built after 12/01/2008