Sensor Adjustment

24 • • • • Printer Operation & Quick Set-Up
The hole and top reflective registration sensor can be adjusted by turning the knob as
shown above. Move the sensor over the desired registration mark. To ensure the
sensor is in the right location - hold the feed lever open and move the stock back and
forth. If the sensor LED in the front panel flashes as the hole passes through the
sensor - it is in the correct location. If the sensor LED does not flash, readjust the
sensor.
NOTE: The hole and top reflective sensor registration is selected from PC Mate
Platinum in the Design Layout Information.
See "Print Registration Sensor" for more detail.
The 686-HT uses a top reflective setting in PcMate. The bottom part of the
sensor assembly is blocked with a metal plate for better reflection.
Users Manual Model 686 / 686 HT