Connecting A Normally Closed Alarm - Bosch VEZ Series User Manual

Autodome easy ii
Hide thumbs Also See for VEZ Series:
Table of Contents

Advertisement

52
en | Alarms and Relay Connections
2.
9.2.2

Connecting a Normally Closed Alarm

1.
Ref. # User Contact Dome
1
2
2.
F.01U.139.424 | 2.0 | 2009.08
From the AutoDome Easy II main menu select Alarm
Setup>Inputs Setup, and set Alarm Input # to N.O. See the
table below for contact and condition details.
AutoDome Easy II Programmed N.O.
Circuit
Open
Closed
Connect the alarm to the appropriate input (1 through 2)
and ground at the AutoDome Easy II.
Figure 9.2 N.C. Normally Closed Connections
Normally
Closed
Common
From the AutoDome Easy II main menu select Alarm
Setup>Inputs Setup, and set Alarm Input # to N.C. See the
table below for contact and condition details.
AutoDome Easy II Programmed N.C.
Circuit
Open
Closed
User Manual
Alarm Indication
Normal
Alarm
Alarm In 1 or Alarm In 2
(Ref. #3)
Ground (Ref. #4)
Alarm Indication
Alarm
Normal
AutoDome Easy II
Color
Brown IN 1 or
Orange IN 2
Green
Bosch Security Systems, Inc.