Bosch VEZ Series User Manual page 83

Autodome easy ii
Hide thumbs Also See for VEZ Series:
Table of Contents

Advertisement

AutoDome Easy II
Alarm Setup Menu Choices:
Menu
Description
Exit
Saves and exits
the menu.
Inputs
Defines physical
Setup
inputs or events
and commands
that can be used
in a rule. There
are twelve (12)
alarm inputs
available.
Inputs 1-2
Defines the type
of physical
input.
Outputs Setup Menu
Exit...
1. Alarm Output
2. Shot
3. Shot
4. Shot
5. Aux On
6. Transmit
7. OSD
8. NONE
9. NONE
10. NONE
11. NONE
12. NONE
Right / Left: Select Mode
Bosch Security Systems, Inc.
Sub-menu / Description
N.O.: Normally open dry contact.
N.C.: Normally closed dry
contact.
Outputs Setup...
N.O.
Front Door
2
99
1
Focus / Iris: Select Type
On-Screen Display Menu Navigation | en
User Manual
1 Physical Output
2-12 Command
Outputs
F.01U.139.424 | 2.0 | 2009.08
77
Default
Setting
N.O.

Advertisement

Table of Contents
loading

Table of Contents