AutoDome Easy II
8
Preparing the Wiring
There are four (4) types of wires required: control, video,
power, and alarm. Each section provides the specifications for
the recommended wire.
CAUTION! Installation should only be performed by qualified
service personnel in accordance with the National Electrical
Code or applicable local codes.
8.1
Power
The recommended power cable is a 2-conductor, 14-18 gage
cable, depending on the distance.
24 VAC to
AutoDome Easy II
12 VDC to
AutoDome Easy II
Table 8.1 Maximum Wire Distances from Power Supply
8.2
Connecting the Power
Figure 8.1 Power Cable
Ref. # Wire
1
2
3
NOTICE! This unit accepts 24 VAC or 12 V DC, 1 A power only.
Do not connect 120 V or 230 V to this camera.
Bosch Security Systems, Inc.
VA /
Watts
18 / 10
10 W
24 VAC/+12 V DC
24 VAC/Grounded
User supplied Power Supply
User Manual
Preparing the Wiring | en
14 AWG
16 AWG
(2.5 mm)
(1.5 mm)
632 ft
398 ft
(193 m)
(121 m)
285 ft
179 ft
(87 m)
(55 m)
Color
Red
Black
n/a
F.01U.139.424 | 2.0 | 2009.08
43
18 AWG
(1.0 mm)
250 ft
(76 m)
112 ft
(34 m)