AutoDome Easy
5.2

Connecting the Video

Coaxial cable terminated with BNC connectors is the most common method for transmitting
composite video. To connect the video, do the following:
1.
2.
5.3

Connecting the Power

To connect the power, do the following:
WARNING! This unit accepts 24 VAC or 12 V DC, 1 A power only. Do not connect 120 V or
!
230 V to this camera.
1.
2.
3.
NOTICE! Use certified / Listed Class 2 power supply transformer only.
i
5.4

Connecting the Alarm Input

The AutoDome Easy provides one (1) alarm input. This alarm input can be activated by dry
contact devices, which triggers the dome camera to move to a pre-position. The default alarm
state is normally open but may be programmed to be normally closed. See
Section 10: Program and Operation for configuring alarm input. To connect the alarm input, do
the following:
1.
2.
3.
Fig. 5.3 N.O. - Normally Open Non-supervised Connections
NOTICE! All the connectors marked GND are common.
i
Bosch Security Systems, Inc.
Terminate the coaxial cable from the head end system with a male BNC connector.
Connect the head end video cable to the yellow Video Out connector from the base of the
camera.
Locate the cable assembly with a two (2) pin mating connector on one end and the
orange and red flying leads on the other end.
Connect one lead of the 12 V DC or 24 VAC power source to the red wire.
Connect one lead of the 12 V DC or 24 VAC power source to the orange wire.
Locate the cable assembly with a two (2) pin blue mating connector on one end and the
blue and violet flying leads on the other end.
Connect the ground of the alarm source dry contact to the blue wire (alarm common).
Connect the alarm out of the alarm source dry contact to the violet wire (alarm input).
Dry
Contact
Installation and Configuration Manual
Alarm Common Blue Wire
Alarm Input Violet Wire
Connections