COMMAND:
SET SELECTIVE CALLING PULSE #1 CODE
SCL 1 CODE= AA
FORMAT:
This command allows the PULSE #1 code to be programmed in the Selective Calling mode of operation.
The code specifies the frequency of the two tones modulated in PULSE #1. The first ASCII character in
the code specifies TONE #1 frequency and the second specifies TONE #2 frequency. The code may
range from A to S for each tone.
COMMAND:
SET SELECTIVE CALLING PULSE #2 CODE
SCL 2 CODE= AA
FORMAT:
This command allows the PULSE #2 code to be programmed in the Selective Calling mode of operation.
The code specifies the frequency of the two tones modulated in PULSE #2. The first ASCII character in
the code specifies TONE #1 frequency and the second specifies TONE #2 frequency. The code may
range from A to S for each tone.
COMMAND:
SET PULSE #1 TONE #1 FREQUENCY
SCL 1 TONE 1= DDDD[.D]
FORMAT:
This command allows changing the standard frequency (set with SCL 1 CODE command) for TONE #1 of
PULSE #1 for the Selective Calling mode of operation. The frequency is specified in Hz using 0.1 Hz
resolution and the range is from 100 to 9999.9 Hz.
COMMAND:
SET PULSE #1 TONE #2 FREQUENCY
SCL 1 TONE 2= DDDD[.D]
FORMAT:
This command allows changing the standard frequency (set with SCL 1 CODE command) for TONE #2 of
PULSE #1 for the Selective Calling mode of operation. The frequency is specified in Hz using 0.1 Hz
resolution and the range is from 100 to 9999.9 Hz.
COMMAND:
SET PULSE #2 TONE #1 FREQUENCY
SCL 2 TONE 1= DDDD[.D]
FORMAT:
This command allows changing the standard frequency (set with SCL 2 CODE command) for TONE #1 of
PULSE #2 for the Selective Calling mode of operation. The frequency is specified in Hz using 0.1 Hz
resolution and the range is from 100 to 9999.9 Hz.
COMMAND:
SET PULSE #2 TONE #2 FREQUENCY
SCL 2 TONE 2= DDDD[.D]
FORMAT:
This command allows changing the standard frequency (set with SCL 2 CODE command) for TONE #2 of
PULSE #2 for the Selective Calling mode of operation. The frequency is specified in Hz using 0.1 Hz
resolution and the range is from 100 to 9999.9 Hz.
COMMAND:
SET SELECTIVE CALLING PULSE #1 TIME
SCL 1 TIME= D.DDD
FORMAT:
This command programs the pulse width of PULSE #1 in the Selective Calling mode of operation. The
range is from 0 to 2.000 S in .001 S steps.
COMMAND:
SET SELECTIVE CALLING PULSE #2 TIME
SCL 2 TIME= D.DDD
FORMAT:
This command programs the pulse width of PULSE #2 in the Selective Calling mode of operation. The
range is from 0 to 2.000 S in .001 S steps.