Aeroflex NAV 2000R Operation Manual page 51

Signal generator
Table of Contents

Advertisement

COMMAND:
IDENTIFICATION WORD DELAY
WORD DELAY= DD[.D]
FORMAT:
This command may be used to set the delay from the end of a Morse code identifier transmission to the
beginning of the next transmission. Word rate as defined above is calculated. Time may be programmed
to produce any word rate from 1.0 to 65.0 s. with 0.1 s. resolution.
COMMAND:
SET 30 Hz FREQUENCY
30 HZ= DD[.D]
FORMAT:
This command changes the 30 Hz frequency. The 30 Hz signal is only generated during VOR mode.
The argument value is specified in Hz with 0.1 Hz resolution.
COMMAND:
SET 90 Hz FREQUENCY
90 HZ= DD[.D]
FORMAT:
This command deviates the 90 Hz frequency. The 90 Hz signal is only generated during the LOC and
G/S modes. The argument value is specified in Hz with 0.1 Hz resolution.
COMMAND:
SET 150 Hz FREQUENCY
150 HZ= DD[.D]
FORMAT:
This command deviates the 150 Hz frequency. The 150 Hz signal is only generated during the LOC and
G/S modes. The argument value is specified in Hz with 0.1 Hz steps.
COMMAND:
SET 90/150 Hz PHASE
PHASE = DDD[.DD]
FORMAT:
This command deviates the 90 Hz and 150 Hz phase relationship. These signals are only generated
during the LOC and G/S type modes. The argument value is specified in degrees with 0.01 degree
resolution and may range from 0 to 359.99 degrees.
COMMAND:
SET 9960 Hz FREQUENCY
9960 HZ= DDDDD[.D]
FORMAT:
This command deviates the 9960 Hz frequency. The 9960 Hz signal is only generated during the VOR
modes. The argument value is specified in Hz with 0.1 Hz resolution. The valid frequency that may be
specified may range from 9,000 to 12,000 Hz.
COMMAND:
SET 1020 Hz FREQUENCY
1020 HZ= DDDDD[.D]
FORMAT:
This command allows the user to deviate the 1020 Hz identification frequency. The 1020 Hz signal is
only generated during the VOR and LOC modes. The units are in Hz with 0.1 Hz resolution and may
range from 10 to 18000 Hz.
COMMAND:
SET MARKER BEACON FREQUENCY
MKR FREQ= DDDDD[.D]
FORMAT:
This command sets the marker beacon frequency to a specific value. This command must follow a
marker beacon mode set command since marker beacon frequency is automatically set to be the default
when the beacon mode changes.
NAV 2000R SIGNAL GENERATOR - REV. 0 – JULY 26, 2007 - PG 3-31