8-238
AP-7131 Access Point Product Reference Guide
AP7131>admin(system.ntp)> set
Description:
Sets NTP parameters for access point clock synchronization.
Syntax:
set mode
<ntp-mode>
server
<idx> <ip>
port
<idx> <port>
intrvl
<period>
time
<time>
zone
<zone>
Example:
admin(system.ntp)>set mode enable
admin(system.ntp)>set server 1 203.21.37.18
admin(system.ntp)>set port 1 123
admin(system.ntp)>set intrvl 15
admin(system.ntp)>set zone 1
For information on configuring NTP using the applet (GUI), see
Enables or disables NTP.
Sets the NTP sever IP address.
Defines the port number.
Defines the clock synchronization interval used between the access point and
the NTP server in minutes (15 - 65535).
Sets the current system time. [yyyy] - year, [mm] - month, [dd] - day of the
month, [hh] - hour of the day, [mm] - minute, [ss] second, [zone -idx] Index of the
zone.
Defines the time zone (by index) for the target country.
Configuring Network Time Protocol (NTP) on page
4-41.