ADDITIONAL COMPONENTS REQUIRED

Vent System: Approved venting listed on page 15 of this installation manual.
Glass Media: Various colors available. See Dealer for details.

INSTALLATION OVERVIEW

NOTE
The qualified installer should follow the procedure best suited for the installation.
1.
Frame an opening for fireplace, allowing for vent installation and type of installation (corner or flat wall application).
2.
If masonry (optional) is used, prepare foundation for the masonry load. A lintel is required to support the added weight above fireplace.
3.
Attach stand-off brackets and nailing flanges to fireplace.
4.
Insert fireplace into framing.
5.
Install hearth (if applicable).
6.
Complete gas line installation.
7.
Complete electrical hook-up. Install any standard or optional electrical components at this time.
8.
Complete venting installation.
9.
Secure fireplace to framing with nailing flanges. Verify all clearances at this point.
10. Install facing material, mantel or cabinetry, allowing room for optional full face doors, if applicable.
11. Install glass media (required).
12. Install finishing material, optional surrounds.
13.
Verify proper operation of fireplace and all components.

PLACEMENT CLEARANCE REQUIREMENTS

This fireplace must be installed on a level surface capable of supporting fireplace and venting.
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of
fireplace.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.

TELEVISION POSITIONING CONSIDERATIONS

Mounting a TV above a fireplace has become common practice. With this in mind, we advise you to read the following paragraphs
carefully before considering installing a television above your fireplace.
Most TV manufacturers specify in their instructions that a TV should not be installed on, near, or above a heat source. Television location
rests solely on the homeowner and Hussong Manufacturing will not be held liable for any adverse affects on a TV located near a Kozy Heat
Fireplace that may be caused by heat.
TV operating temperature is also affected by wall and mantle construction material. It is the customers responsibility to satisfy themselves
that their TV mounting and mantle design will not exceed the listed maximum operating temperature of their electronic goods.