The appliance is required to be inspected at least once a year by a professional service person.
The compartment below firebox must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting,
bedding materials, or other fibrous materials. Use a vacuum to clean all components at least once a year.
INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE
INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING
NOTE
MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN
CONTROL BOARD SYSTEM
Annual cleaning of burner system is required. Vacuum all components thoroughly.
Visually check for blocked port holes, especially near the pilot. Blocked port holes may cause delayed ignition.
Visually check pilot light and burner when in operation. Flames should be steady, not lifting or floating.
Pilot
Figure 19a
FAN
The fan should be disconnected from electrical current, and cleaned (vacuumed) every six months. The bearings are sealed and require no oiling.
VENT SYSTEM
Annual examination of venting system by a qualified agency is required.
IF VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL
INSTALLATION.
The flow of combustion and ventilation air must not be obstructed.
GLASS CLEANING & REPLACEMENT
Clean glass only when cool and only with non-abrasive cleansers.
CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or
qualified service person.
Use protective gloves to handle any broken or damaged glass assembly components.
The glass assembly, part #SL42-057T, shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc.
Replacement of glass & frame assembly, part #SL42-057T, must only be performed by a licensed or qualified service person.
DO NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass door assembly.
IMPORTANT
ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
CAUTION
KEEP APPLIANCE AREA CLEAR OF COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.

MAINTENANCE

MAINTENANCE
Burner Orifice
19