Vertical Vent System Clearances; Restrictor; Venting (Cont.) - kozy heat SLA-42 Installation And Operation Manual

Direct vent linear fireplace
Table of Contents

Advertisement

ALL APPROVED VERTICAL PIPE
VERTICAL TERMINATIONS
NOTE
Horizontal Vent Heat Shield is not used on vertical venting configurations.
MIN. / MAX. VERTICAL VENTING
APPLIES TO NAT AND LP INSTALLATIONS:
MINIMUM: 2ft. (610mm) + cap.
MAXIMUM: 50ft. (15.24m) + cap.

RESTRICTOR

Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace
installation is complete a restrictor (included with fireplace components packet) may be required or may need to be removed or modified.
Please refer below for installation instructions if installing the restrictor in conjunction with venting.
Page 27 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting
is completed.
Large Restrictor
Remove tab (s) to
create small restrictor
Figure 18b
VENTING

VERTICAL VENT SYSTEM CLEARANCES

TOP
1 inch (25mm)
Figure 18a
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
18
BOTTOM
1 inch (25mm)
Slide restrictor into exhaust pipe on top of fireplace with tabs
pointing towards you prior to attaching venting.
SIDES
1 inch (25mm)
TERMINATION CAP
MINIMUM: 2ft. (610mm)
MAXIMUM: 50ft. (15.24m)