Optional Blower # 156000
Connect the gas supply line to the stove,
before installing the Blower.
Use a 90° Elbow off the control valve to create
clearance required for the blower installation.
1. Unpack and check the contents of the blower kit.
Contact your dealer if any damage is evident or
parts are missing. See fig. 43.
2. Attach the Snapstat Bracket to the studs located in
the middle of the firebox floor using the two M6
hex nuts and a 10 mm wrench. See fig. 44.
3. Attach the Blower Bracket to the stove using the
two M6 flange head hex bolts as shown in fig. 44.
4. Attach the Duct Deflectors using the two #7 x 1/2"
screws together with the finger guard mounting
screws already in place. See #7 and #11 in fig. 43.
5. Install the Blower with the duct openings oriented
up and forward. See fig. 45. Feed the wire harness
through the bracket opening and secure the blower
to the bracket with the wingscrew.
6. Attach either Snapstat wire connector to either
Snapstat terminal. See fig. 45.
7. Install the Snapstat by sliding it all the way into the
slot in the bottom of the Snapstat Bracket as shown
in figs. 43 and 45.
8. Connect the male wire harness connector to the
female wire harness connector already installed in
the stove. See fig. 45.
9. Connect power cord to outlet.
THIS BLOWER MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH
LOCAL CODES OR, IN THE ABSENCE OF
LOCAL CODES, WITH THE CURRENT
ANSI/NFPA 70, NATIONAL ELECTRICAL
CODE OR CSA C22.1-CANADIAN
ELECTRICAL CODE.
THIS UNIT IS SUPPLIED WITH A
THREE-PRONG (GROUNDING) PLUG
FOR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY
GROUNDED THREE-PRONG
RECEPTACLE. DO NOT CUT OR
REMOVE THE GROUNDING PRONG
FROM THE PLUG.
ALWAYS DISCONECT THE POWER
SUPPLY WHEN PERFORMING ANY
SERVICE ON THE FIREPLACE INSERT.
7 7 7 7 7
1 1 1 1 1
C C C C C on
on
on
ten
ten
tents ts ts ts ts
onten
on
ten
1. Blower
2. Mounting Bracket
3. Snapstat Wire Harness
4. Control Switch Wire Harness
5. Snapstat
6. Snapstat Bracket
7. Blower Duct Deflector (2)
8. M6 Hex Head Flange Nuts (2)
9. M6 x 12 Hex Head Flange Bolts (2)
10. M6 x 12 Wingscrew
11. #7 x 1/2" phillips screw (2)
Figure 43. Blower Kit Components
Hex Head
Flange Bolts
Blower Bracket
Figure 44. Attach Snapstat and Blower Brackets.
6 6 6 6 6
5 5 5 5 5
11 11 11 11 11
3 3 3 3 3
9 9 9 9 9
4 4 4 4 4
7 7 7 7 7
T T T T T ools R
ools R
ools R
ools Requir
ools R
equired
equir
equir
equir
ed
ed
ed
ed
• 10 mm wrench
* short phillips screwdriver
* Safety Glasses
* Work Gloves
Snapstat
Bracket
Hex Head
Flange Nuts
8 8 8 8 8
2 2 2 2 2
10 10 10 10 10
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents