Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove
to Combustibles:
See figs. 2-4.
Rear:
2" (51 mm)
Ceiling:
32 1/4" (819 mm)
Corner:
2" (51 mm)
Sides:
3" (76 mm)
Minimum Clearances from the Vent Pipe to
Combustibles:
Horizontal Run:
Off the top of the pipe
Off the sides and bottom 1" (25 mm)
Vertical Run:
All sides
1" (25 mm)
Minimum Ceiling or Alcove Height
Max. Top Trim Depth = 1”
Figure 2. Mantel and Trim Clearance specifications.
Back of bottom plate is flush with the fireplace face.
Subtract 2 1/4" with Short Legs.
2" (51 mm)
Max. Mantel Depth
12.5”
10.25”
8”
5.75”
3.5”
Min. Mantel Depth
2” (5.1cm)
3"
(76 mm)
Figure 3. Parallel Installation Clearances.
2"
51 mm
Figure 4. Corner Clearances.
Alcove Installation
Maximum Alcove Depth:
Minimum Alcove Width: 31 3/4" (80.6 cm)
Minimum Ceiling Height:
With Short Legs (6") :
Alcove dimensions result from test
configurations, not stove clearance
specifications.
2"
(51 mm)
To Rear Wall
3"
(76 mm)
2"
51 mm
24" (61 cm)
61" (155 cm)
59" (150 cm)