Jøtul GF 373 BF Installation And Operation Instructions Manual

Jøtul GF 373 BF Installation And Operation Instructions Manual

Balanced flue gas stove;

Advertisement

Installation and

Operation Instructions

WARNING: If the information in
these instructions is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or death.
– Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas
supplier from a neighbour's phone.
Follow the gas supplier's
instruction.
• If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
139807_R4 GF 373 BF CE 7/17
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 373 BF

  • Page 1: Operation Instructions

    139807_R4 GF 373 BF CE 7/17 Installation and Operation Instructions WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or...
  • Page 2 139807_R4 GF 373 BF CE 7/17 EU Gas Appliance Directive (GAD) Company name: Jøtul North America, Inc. Postal address: 55 Hutcherson Drive Postcode and City Gorham, Maine Country United States of America Telephone number: +0 1 207 591 6601 e-mail address...
  • Page 3: Table Of Contents

    139807_R4 GF 373 BF CE 7/17 Table of Contents 1. Technical Information ......4 2. General Information ......5 3. Safety Precautions ........5 4. Installer Information ......6 5. User Information ........10 6 Illustrations ..........12 7. Remote Control ........18 8. Appendix..........22 9.
  • Page 4: Technical Information

    139807_R4 GF 373 BF CE 7/17 1. Technical Information THIS APPLIANCE IS FACTORY-EQUIPPED TO This appliance is configured for gas USE EITHER NG (G20/G25) OR LPG (G31). categories E (I2E) and K (I2K) and is suitable for the use of G and G+ distribution gases IT IS NOT FUEL CONVERTIBLE.
  • Page 5: General Information

    WARNING! If you detect an odour of gas: This product, the Jøtul GF 373 BF CE may only be used   • Do not light the Stove or any other appliance.
  • Page 6: Installer Information

    139807_R4 GF 373 BF CE 7/17 4. Installer Information Minimum clearances from combustible Position of Outdoor Exhaust Hood material to vent system • If the clearance from ground level to the terminal exhaust hood is less than 3 m, the hood must be protected by a wire mesh guard.
  • Page 7: R4 Gf 373 Bf Ce

    Adjust Exhaust Restrictor Plate (Position 2) Flueing options 1. Remove top casting and decorative trim pieces from The GF 373 BF CE is capable of a variety of flueing top of unit. configurations using an assortment of balanced flue 2. Open Door.
  • Page 8: Log Set Installation

    139807_R4 GF 373 BF CE 7/17 Log Set Installation THIS APPLIANCE IS NOT FUEL CONVERTIBLE. WARNING: The ceramic fuel effect (logs) should only SEE RATING DATA PLATE FOR APPROPRIATE be arranged by qualified service engineer. Under no FUEL SPECIFICATIONS. circumstances may extra elements be added to the DO NOT USE ANY OTHER FUELS.
  • Page 9: Battery Installation

    139807_R4 GF 373 BF CE 7/17 Commissioning Battery Installation Inspection of the Pilot Flame The TESC valve requires three, AA alkaline batteries The pilot assembly flame should have two flames as be installed within the central battery compartment. shown in fig. 13. The rear flame should fully engulf the The batteries supplied were used to test the valve and thermo-element that controls gas flow through the valve.
  • Page 10: User Information

    139807_R4 GF 373 BF CE 7/17 5. User Information Operating Instructions Lighting Instructions Commissioning, Lighting NOTE! Odours may be present when using the stove for the WARNING: THIS APPLIANCE first time: FEATURES ELECTRONIC When used for the first time and hot, the appliance will PILOT IGNITION.
  • Page 11: Battery Replacement

    139807_R4 GF 373 BF CE 7/17 Maintenance NOTE: If the appliance will not be used for an extended period, such as during summer or storage, The complete installation, including the gas supply, disconnect power by setting the valve Master firebox, burner components and vent system, must be switch to the Left (O).
  • Page 12: Illustrations

    139807_R4 GF 373 BF CE 7/17 6. Illustrations Figure 1. 397mm Figure 2. Gas Supply Line Connection 76mm 324mm 178mm Figure 3. 349mm 127mm 127mm Figure 4. 397mm 76mm 324mm 178mm 178mm...
  • Page 13 139807_R4 GF 373 BF CE 7/17 Figure 5. Vent Configurations. 1600 mm maximum horizontal run (including the 600 mm attached terminal length) if vertical rise is greater than 1500 mm and no greater than 10 metres. NOTE: All horizontal flue lengths must have a 5°...
  • Page 14 139807_R4 GF 373 BF CE 7/17 Fig. 8. Install Bottom Log. Fig. 9. Install Right Log. Fig. 11. Install Ember Stones. Fig. 10. Install Left Log. SECTION SUPPLY-SUPPLY Manifold Supply Line Pressure Connection SUPPLY FITTING MANIFOLD ACCESS THRU FRONT Fig. 13. Correct Pilot flame pattern.
  • Page 15 139807_R4 GF 373 BF CE 7/17 Fig. 15. Air shutter control. White Master Switch, Red LED Function Lamp ON / OFF Battery Compartment Decrease Cover Release Flame Battery Compartment Lever Burner Power Increase ON / OFF Flame Fig. 16. Valve Operation Controls.
  • Page 16 139807_R4 GF 373 BF CE 7/17 M410082697 M82652 M82650 100 / 150mm flue adaptor M82653 M82654 M82668 M87379 M87913 M30170 M82659 M82658 M82667 M82655 M87196 M82661   Figure 17. Muelink and Grol flue components. All balanced flue accessories include locking bands.
  • Page 17: Remote Control

    139807_R4 GF 373 BF CE 7/17 7. Remote Control Operation Before using the remote handset... Familiarize yourself with all the handset functions and complete the Remote Control Setup procedure described in this section. Handset Functions Insert two, AA batteries into the rear compartment or the handset.
  • Page 18 139807_R4 GF 373 BF CE 7/17 Remote Control Setup After successful batteries 4. Setting the Hour installation, the Handset will display as shown in fig. 19. As • Press and release the + or – supplied, the handset is already...
  • Page 19 139807_R4 GF 373 BF CE 7/17 8. Paging the handset 11. Sleep mode (Zzz) in Manual Operation If you have misplaced the handset (and it is in range of Sleep mode is used to set a period of time after which the burner will turn off.
  • Page 20 139807_R4 GF 373 BF CE 7/17 14. Pairing the Remote Control Although the remote control is paired with the stove at the factory, it may become necessary to cancel the pairing and re-synchronize the two, follow the steps below. NOTE: A new pairing can be made accidentally necessary by pressing the (+) and (-) buttons on the remote control or on the TESC valve control simultaneously for 5 seconds.
  • Page 21: Appendix

    139807_R4 GF 373 BF CE 7/17 8. Appendix A Illustrated Part Breakdown Figure 26. GF 373 BF CE Firebox components No. Part Number Description No. Part Number Description 224710 Intake Manifold 9911 Bolt, Hex Cap, M6x45, DIN 933, Class 8.8, Blk...
  • Page 22 139807_R4 GF 373 BF CE 7/17 Figure 27. GF 373 BF CE Exterior components No. Part Number Description Part Number Description 223220 Plate, Centering, GF 370 117874 Bolt, Hex Hd M8 x 16 Ser Flange Blk 22606992 Hinge, Door, MB...
  • Page 23 139807_R4 GF 373 BF CE 7/17 Supply Tap (A) Manifold Tap (B) Figure 28. GF 373 BF CE Burner and Valve Assembly Part Number Description Part Number Description 156812 Burner Weldment 221390 Primary Air Shutter 226001 Spud Plate Weldment 129670...
  • Page 24 139807_R4 GF 373 BF CE 7/17 Appendix B Top Plate Shims 1. Remove the Top Plate. 2. Remove the three shims highlighted in the illustration below. 3. Matte Black Stoves: Replace the Top Plate and discard the shims. White Enamel Stoves: Locate the three larger shims...
  • Page 25: Warranty

    This warranty policy applies to gas products identified by the 3) Damage due to service performed by an installer, service agency or Jøtul trade name GF 373 BF CE as set forth below. gas supplier, unless otherwise agreed to in writing by JØTUL.
  • Page 26: Service Record

    Company: Date: this user manual and make sure it is available to service Service details: personnel. Model Name: Jøtul GF 373 BF CE Serial No: (on Rating Data Plate) Purchase Date: Name of Installer: Annual service - year 6 Sign.:...
  • Page 27 139807_R4 GF 373 BF CE 7/17...
  • Page 28 139807_R4 GF 373 BF CE 7/17 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that these instructions be carefully read and understood. Jøtul maintains a policy of continuous product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.

Table of Contents