Installation (for qualified installers only)
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies.
S ide
k
Wall
l
Mantel Clearances
The maximum mantel depth is 12" (305mm).
NOTE: The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Mantel Height
Above B as e of Ins ert (n)
© Travis Industries
n
m
p
x
35"(889mm)
34"(864mm)
33"(839mm)
32"(813mm)
31"(788mm)
k Sidewall to Insert
l Side Facing
(non-combustible)
m Top Facing*
(non-combustible)
n 12" Mantel* (combustible
or non-combustible)
n 4" Mantel* (combustible
or non-combustible)
p Hearth Extension to the
Front
x Extension onto Hearth
* Measured from the base of the insert.
NOTE: the non-combustible top facing must
extend 32.375" (823mm) above the base of the
insert or to the bottom of the mantel (whichever
is less).
Maximum Mantel Depth
4140811
11
Minimum
Clearances
5"
127mm
3.375"
86mm
32.375"
823mm
34.5"
877mm
33.5"
851mm
1.75"
45mm
0"
0mm
100-01340