Installation (for qualified installers only)

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture and
draperies.
Mantel Clearances
The maximum mantel depth is 12" (305mm).
NOTE: The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Mantel Height
Above Base
of Fireplace
© Travis Industries
35"+(889mm+)
34"(864mm)
33"(839mm)
32"(813mm)
31"(788mm)
5/20/2021 - 1558
k
Sidewall to Insert
l
Side Facing
(non-combustible)
m Top Facing*
(non-combustible)
n
12" Mantel* (combustible
or non-combustible)
n
4" Mantel* (combustible
or non-combustible)
p
Hearth Extension to the
Front of Insert
x
Extension onto Hearth
1 Piece Panel
1 Piece Panel w/Trim Kit
* Measured from the base of the insert.
NOTE: the non-combustible top facing must extend
32-3/8" (823mm) above the base of the insert or to
the bottom of the mantel (whichever is less).
Maximum Mantel Depth
Minimum
Clearances
5" (127mm)
3-3/8 " (86mm)
32-3/8" (823mm)
34-1/2" (877mm)
33-1/2" (851mm)
0" (0mm)
0" (0mm)
1-1/4" (32mm)
430 MF GSR2