Leveling Bolts

This heater includes front and rear leveling bolts to accommodate fireplaces with a step-down firebox.
NOTE: To access the rear leveling bolts, remove the burner (see page 46).
The leveling bolt holes are shown below.
1. Remove the cover and gasket to access the rear leveling bolt. Replace after adjustment.

Electrical Requirements

Travis Industries manufactures a wiring kit specifically for inserts (sku 97200315). This kit allows installers to
wire 120 volt AC power into a fireplace directly to the insert, eliminating the need for an external power cord.
Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.