Fireplace Placement Requirements
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent
•
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
•
Fireplace should be located out of traffic and away from furniture and avoid burns.
•
Fireplace must be placed so the gaps below and above the glass frame do not become blocked.
•
Fireplace may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces
when determining a location.
Clearances
(a) Clearance to Side of Fireplace 1/2" (13mm). Do not place insulation in this space.
NOTE: Drywall (or other combustible) may contact the first ½" of the sides of the fireplace.
(b) Clearance to Back of Fireplace 1/2" (13mm). Do not place insulation in this space.
(c) When installed, walls in front of the fireplace must be a minimum 0" (0mm) to the side of the fireplace
standoffs.
Raised Fireplaces
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace and vent.
•
The base of the fireplace must be a minimum 60" below the room ceiling.
The top of the control door (firebox opening) is approximately 8-3/4" (223mm) above the base of
the fireplace. For a typical raised fireplace of 36" (915mm), place the fireplace on a platform 27.25"
(693mm) tall.